| 1 Definition | 2 Functional Requirements | 3 Syntax | 4 Semantics |
1 Definition
Physiological Signal Qualifier is a set of Data providing additional information on Physiological Signal Data for potential use by a machine.
The combination of Physiological Signal Data and Physiological Signal Qualifier is called Physiological Signal Object, specified by AIH-HSP V1.0.
2 Functional Requirements
Physiological Signal Qualifier must allow the expression of the following Elements:
- Sub-Type
- Format
- Attributes
Users needing additional entries in the Physiological Signal Qualifier or support of new Qualifiers should make a documented request to the MPAI Secretariat. Requests will be considered by the appropriate MPAI committee.
3 Syntax
https://schemas.mpai.community/TFA/V1.5/data/PhysiologicalSignalQualifier.json
4 Semantics
- Sub‑Types
- ECG (Electrocardiogram)
- Resting 12‑lead ECG
- Exercise / Stress ECG
- Signal‑Averaged ECG (SAE)
- Heart Rate Variability (HRV)
- Ambulatory ECG (Holter)
- Wearable ECG
- PPG (Photoplethysmography)
- Reflective PPG
- Transmissive PPG
- Multi‑wavelength PPG
- Wearable PPG
- EMG (Electromyography)
- Surface EMG (sEMG)
- Intramuscular EMG
- High‑density EMG
- EOG (Electrooculography)
- Horizontal/vertical EOG
- Blink detection EOG
- Saccade tracking EOG
- Respiration
- Airflow
- Respiratory effort (thoracic/abdominal belts)
- Capnography (CO₂ waveform)
- GSR / EDA (Electrodermal Activity)
- Skin conductance
- Skin resistance
- Tonic/phasic EDA
- Blood Pressure Waveform
- Arterial pressure waveform
- Pulse transit time waveform
- Continuous non‑invasive BP waveform
- Formats
- ECG Formats
- ECG (Electrocardiogram)
-
- HL7 aECG (Annotated ECG)
- SCP‑ECG (Standard Communications Protocol for Computer‑Assisted Electrocardiography)
- DICOM‑ECG (DICOM Waveform for ECG)
- ecgML (XML‑based ECG format)
- mECGML (Mobile ECG Markup Language)
- ML‑ECG (Machine Learning ECG format)
- MFER (Medical Waveform Format Encoding Rules)
- Philips XML (Philips ECG XML format)
- ecgAware (ECG markup for ambulatory monitoring)
- EDF / EDF+ (General biosignal format)
- BDF (BioSemi Data Format)
- WFDB (PhysioNet waveform format)
- PPG Formats
-
- OpenSignals (Biosignal format used by BITalino and wearables)
- EDF / EDF+
- BDF
- WFDB
- HDF5 (Large biosignal datasets)
- PPG‑BDF (BioSemi PPG variant)
- PPG‑CSV/TSV (Common export formats)
- EMG Formats
-
- SENIAM‑compatible CSV/TSV (Standard EMG electrode placement & data conventions)
- EDF / EDF+
- BDF
- WFDB
- OpenSignals
- HDF5
- EMG‑MAT (MATLAB‑based EMG format)
- EOG Formats
-
- EDF / EDF+
- BDF
- WFDB
- OpenSignals
- HDF5
- EOG‑MAT
- Respiration Formats
-
- EDF / EDF+
- WFDB
- DICOM‑Waveform (for capnography)
- HDF5
- Resp‑CSV/TSV
- GSR / EDA Formats
-
- OpenSignals
- EDF / EDF+
- WFDB
- HDF5
- EDA‑CSV/TSV
- Blood Pressure Waveform Formats
-
- DICOM‑Waveform
- WFDB
- EDF / EDF+
- HDF5
- BP‑CSV/TSV