Go To MPAI-OSD AI Modules

1 Function 2 Reference Model 3 Input/Output Data
4 SubAIMs 5 JSON Metadata 6 Profiles
7 Reference Software 8 Conformance Texting 9 Performance Assessment

1 Functions

Ultrasound Scene Description (OSD-USD) V1.3 produces the Descriptors of a Scene composed by Ultrasound Objects and Scenes:

Receives Space-Time of the input Objects having the same time base.
Ultrasound Objects Individual Ultrasound Objects.
Scene Descriptors Scene the Objects belong to.
Integrates Space-Time and Ultrasound Object with Scene Descriptors.
Produces Ultrasound Scene Descriptors Output#1 of AIM
Alert Output#2 of AIM signalling potential anomalies in Object.

2 Reference Model

The Reference Architecture is depicted in Figure 1.

Figure 1 – The Ultrasound Scene Description (OSD-USD) AIM

3 Input/Output Data

Table 1 specifies the Input and Output Data of the Ultrasound Scene Description (OSD-USD) AIM. .

Table 1 – I/O Data of the Ultrasound Scene Description (OSD-USD) AIM

Input Description
Space-Time Space-Time of input Objects.
Ultrasound Objects Input Ultrasound Objects.
Scene Descriptors Input Scene Descriptors.
Output Description
Ultrasound Scene Descriptors The output Ultrasound Scene Descriptors.
Alert Data signalling potential anomalies in Object.

4 SubAIMs

No SubAIMs.

5 JSON Metadata

https://schemas.mpai.community/OSD/V1.3/AIMs/UltrasoundSceneDescription.json

6 Profiles

No profiles.

7 Reference Software

8 Conformance Testing

Table 2 provides the Conformance Testing Method for OSD-USD AIM.

If a schema contains references to other schemas, conformance of data for the primary schema implies that any data referencing a secondary schema shall also validate against the relevant schema, if present and conform with the Qualifier, if present.

Table 2 – Conformance Testing Method for OSD-USD AIM

Receives Space-Time Shall validate against Space-Time schema.
Ultrasound Objects Shall validate against Ultrasound Object schema.
Media-specific Data shall conform with their Qualifiers.
Scene Descriptors Shall validate against Scene Descriptors schema.
Produces Ultrasound Scene Descriptors Shall validate against Ultrasound Scene Descriptors schema.
Alert Shall validate against Alert schema.

9 Performance Assessment

Go To MPAI-OSD AI Modules