| 1 Definition | 2 Functional Requirements | 3 Syntax | 4 Semantics |
1 Definition
EEG Qualifier is a set of Data providing additional information on EEG Data for potential use by a machine.
The combination of EEG Data and EEG Qualifier is called EEG Object, specified by AIH-HSP V1.1.
2 Functional Requirements
EEG Qualifier should allow the expression of the following Elements:
- Sub-Type
- Format
Users needing additional entries in the EEG Qualifier or support of new Qualifiers should make a documented request to the MPAI Secretariat. Requests will be considered by the appropriate MPAI committee.
The Qualifier may include Findings: what the data show. Each Finding has an identifier (FindingID), a Code, the Coding System of the Code, chosen among those of this domain, the name of the label set when the Code is from a data set’s own labels (LabelSet), and where in the data the Finding is (Where). Who set a Finding and how sure that source is are not part of the Qualifier: they are in the AIH Data that carries the data (FindingTrust).
3 Syntax
https://schemas.mpai.community/TFA/V1.5/data/EEGQualifier.json
4 Semantics
-
Sub-Types
- Electroencephalography (EEG)
- sEEG (stereoelectroencephalography)
- Magnetoencephalography (MEG)
- Yokogawa MEG
- Biosemi EEG
- NeuroMag MEG
- Electroencephalography (EEG)
-
Formats
- EEG
- Minimum EEG-MAT
- Standard EEG-MAT format
- MEG
- Minimum MEG-MAT
- Standard MEG-MAT format
- EDF/EDF+
- BrainVision
- GDF (BIOSIG)
Findings
| Label | Description |
| Findings | What the data show, each Finding coded in a vocabulary of this domain: the labels a Neural Network Model learns from and is checked against. |
| FindingID | Identifier of the Finding; the FindingTrust of AIH Data refers to it. |
| Code | The Finding, as the Coding System writes it. |
| CodingSystem | One of: HED, SNOMEDCT, ICD10, ICD11, DatasetLabelSet. |
| LabelSet | The name of the label set when the CodingSystem is DatasetLabelSet (a data set’s own labels, e.g. NIH ChestX-ray14). |
| Where | Where in the data the Finding is: Start, End (seconds from the start of the recording); Channels. |
5 References
- Standard data format MEG/EEG; https://vbmeg.atr.jp/docs/v22/attachFile/vbmeg2_job_functions/Standard-format-MEG_EEG_2_0_0_en.pdf