1 Definition 2 Functional Requirements 3 Syntax 4 Semantics

1 Definition

EEG Qualifier is a set of Data providing additional information on EEG Data for potential use by a machine.

The combination of EEG Data and EEG Qualifier is called EEG Object, specified by AIH-HSP V1.1.

2 Functional Requirements

EEG Qualifier should allow the expression of the following Elements:

  1. Sub-Type
  2. Format

Users needing additional entries in the EEG Qualifier or support of new Qualifiers should make a documented request to the MPAI Secretariat. Requests will be considered by the appropriate MPAI committee.

The Qualifier may include Findings: what the data show. Each Finding has an identifier (FindingID), a Code, the Coding System of the Code, chosen among those of this domain, the name of the label set when the Code is from a data set’s own labels (LabelSet), and where in the data the Finding is (Where). Who set a Finding and how sure that source is are not part of the Qualifier: they are in the AIH Data that carries the data (FindingTrust).

3 Syntax

https://schemas.mpai.community/TFA/V1.5/data/EEGQualifier.json

4 Semantics

  1. Sub-Types

    1. Electroencephalography (EEG)
      1. sEEG (stereoelectroencephalography)
    2. Magnetoencephalography (MEG)
      1. Yokogawa MEG
      2. Biosemi EEG
      3. NeuroMag MEG
  2. Formats

  1. EEG
    1. Minimum EEG-MAT
    2. Standard EEG-MAT format
  2. MEG
    1. Minimum MEG-MAT
    2. Standard MEG-MAT format
  3. EDF/EDF+
  4. BrainVision
  5. GDF (BIOSIG)

Findings

Label Description
Findings What the data show, each Finding coded in a vocabulary of this domain: the labels a Neural Network Model learns from and is checked against.
FindingID Identifier of the Finding; the FindingTrust of AIH Data refers to it.
Code The Finding, as the Coding System writes it.
CodingSystem One of: HED, SNOMEDCT, ICD10, ICD11, DatasetLabelSet.
LabelSet The name of the label set when the CodingSystem is DatasetLabelSet (a data set’s own labels, e.g. NIH ChestX-ray14).
Where Where in the data the Finding is: Start, End (seconds from the start of the recording); Channels.

5 References

  1. Standard data format MEG/EEG; https://vbmeg.atr.jp/docs/v22/attachFile/vbmeg2_job_functions/Standard-format-MEG_EEG_2_0_0_en.pdf