Go to MPAI-OSD V1.5 AI Modules

Function
Ref. Model
I/O Data
SubAIMs
JSON MData
Profiles
Ref. Software
Conformance
Performance

1 Functions

The Basic Ultrasound Scene Description (OSD-BUS) AIM describes the acquired Basic Ultrasound Object as Basic Ultrasound Scene Descriptors. It raises an Alert when what it describes warrants one, without waiting for integration. Spatial Attitude and Basic Environment Descriptors are optional inputs, so that the same AIM serves applications that have something to connect to them and applications that do not.

Receives Basic Ultrasound Object The acquired Basic Ultrasound Object.
Spatial Attitude Spatial Attitude of the application (ego), when it has one.
Basic Environment Descriptors Descriptors of the environment, when the application has them.
Produces Basic Ultrasound Scene Descriptors The description of the Ultrasound scene.
Alert Raised when what is described warrants one.

2 Reference Model

Figure 1 depicts the Reference Model of the Basic Ultrasound Scene Description (OSD-BUS) AIM.

Basic Ultrasound Scene Description OSD-BUS AIM

Figure 1 – Reference Model of the Basic Ultrasound Scene Description (OSD-BUS) AIM

3 I/O Data

Table 1 specifies the Input and Output Data of the Basic Ultrasound Scene Description (OSD-BUS) AIM. Links are to the Data Type specifications.

Table 1 – I/O Data of the Basic Ultrasound Scene Description (OSD-BUS) AIM

Input Data Type Description
Basic Ultrasound Object Basic Ultrasound Object The acquired Basic Ultrasound Object.
Spatial Attitude Spatial Attitude (optional) (Port Number 1) Spatial Attitude of the application (ego), when it has one.
Basic Environment Descriptors Basic Environment Descriptors (optional) (Port Number 1) Descriptors of the environment, when the application has them.
Output Data Type Description
Basic Ultrasound Scene Descriptors Basic Ultrasound Scene Descriptors The description of the Ultrasound scene.
Alert Alert (optional) (Port Number 1) Raised when what is described warrants one.

4 SubAIMs

No SubAIMs.

5 JSON Metadata

https://schemas.mpai.community/OSD/V1.5/AIMs/BasicUltrasoundSceneDescription.json

6 Profiles

No Profiles.

7 Reference Software

Not part of this specification.

8 Conformance Testing

Table 2 provides the Conformance Testing Method for the OSD-BUS AIM.

If a schema contains references to other schemas, conformance of data for the primary schema implies that any data referencing a secondary schema shall also validate against the relevant schema, if present, and conform with the Qualifier, if present.

Table 2 – Conformance Testing Method for the OSD-BUS AIM

Receives Basic Ultrasound Object (Basic Ultrasound Object) Shall validate against the Basic Ultrasound Object schema.
Spatial Attitude (Spatial Attitude) Shall validate against the Spatial Attitude schema.
Basic Environment Descriptors (Basic Environment Descriptors) Shall validate against the Basic Environment Descriptors schema.
Produces Basic Ultrasound Scene Descriptors (Basic Ultrasound Scene Descriptors) Shall validate against the Basic Ultrasound Scene Descriptors schema.
Alert (Alert) Shall validate against the Alert schema.

9 Performance Assessment

Not part of this specification.

Go to MPAI-OSD V1.5 AI Modules