| Definition | Functional Requirements | Syntax | Semantics | Conformance Testing | Performance Assessment |
1 Definition
A Data Type describing the arrangement of the Ultrasound Objects in a Scene.
2 Functional Requirements
A Basic Ultrasound Scene Geometry must include:
- The Basic Ultrasound Scene Geometry Header
- The ID of the Basic Ultrasound Scene Geometry.
- The ID of the Ultrasound Objects in the Ultrasound Scene.
- The Space-Time information of the Ultrasound Objects inside the Ultrasound Scene.
A Basic Ultrasound Scene Geometry may include:
- The ID of a Virtual Space (M-Instance) where it is or it is intended to be located.
- The ID of a U-Environment where it is or it is intended to be located.
- The Qualifiers of the Basic Ultrasound Object Data.
- The Space-Time information of the Basic Ultrasound Scene.
- Information about this Basic Ultrasound Scene Geometry.
- Descriptive Metadata.
3 Syntax
https://schemas.mpai.community/OSD/V1.5/data/BasicUltrasoundSceneGeometry.json
4 Semantics
| Label | Description |
| Header | Basic Ultrasound Scene Geometry Header – Standard “OSD-BUG-Vx.y” |
| MInstanceID | Identifier of the M-Instance. |
| UEnvironment | Identifier of the U-Environment. |
| UltrasoundSceneGeometryID | ID of this Basic Ultrasound Scene Geometry instance. |
| UltrasoundSceneGeometryTime | Space and Time of Ultrasound Scene Geometry. |
| UltrasoundObjectCount | Number of Ultrasound Objects in Scene. |
| UltrasoundSceneGeometrySpaceTime | Space and Time of Ultrasound Scene Geometry. |
| BasicUltrasoundSceneObjects[] | Set of Data related to Ultrasound Objects in the Ultrasound Scene. |
| – BasicUltrasoundSceneObjectQualifiers | Qualifiers of the Ultrasound Object in the Ultrasound Scene. |
| – BasicUltrasoundSceneObjectSpaceTime | Space and Time of Ultrasound Object in the Ultrasound Scene. |
| DataXMData | Information on this Basic Ultrasound Scene Geometry instance. |
| DescrMetadata | Descriptive Metadata |
5 Conformance Testing
A Data instance Conforms with Basic Ultrasound Scene Geometry (OSD-BUG) if:
- The Data validates against the Basic Ultrasound Scene Geometry’s JSON Schema.
- All Data in the Basic Ultrasound Scene Geometry’s JSON Schema
- Have the specified type
- Validate against their JSON Schemas
- Conform with their Data Qualifiers.