1 Definition
A Data Type including the arrangement of the Ultrasound Objects and the Ultrasound Sub-Scenes in a scene.
2 Functional Requirements
An Ultrasound Scene Geometry instance must include:
- The Ultrasound Scene Geometry Header
- The ID of the Ultrasound Scene Geometry.
- The ID and the Space-Time information of the Ultrasound Objects in the Ultrasound Scene.
- The ID and the Space-Time information of the Sub-Ultrasound Scenes in the Ultrasound Scene.
An Ultrasound Scene Geometry instance may include:
- The ID of a Virtual Space (M-Instance) to which it refers.
- The ID of a U-Environment to which it refers.
- The Space-Time information of this Ultrasound Scene Geometry instance.
- Information about this Ultrasound Scene Geometry.
- Descriptive Metadata.
3 Syntax
https://schemas.mpai.community/OSD/V1.5/data/UltrasoundSceneGeometry.json
4 Semantics
| Label | Description |
| Header | Ultrasound Scene Geometry Header – Standard “OSD-USG-Vx.y” |
| MInstanceID | Identifier of the M-Instance. |
| UEnvironment | Identifier of the U-Environment. |
| UltrasoundSceneGeometryID | ID of this Ultrasound Scene Geometry instance. |
| UltrasoundSceneGeometryTime | Space and Time of Ultrasound Scene Geometry. |
| UltrasoundSceneGeometrySpaceTime | Space and Time of Ultrasound Scene Geometry. |
| ObjectCount | Number of Objects in Ultrasound Scene. |
| UltrasoundSceneObjects[] | Set of Data related to Ultrasound Objects in the Ultrasound Scene. |
| – UltrasoundSceneObjectSpaceTime | Space and Time of a Ultrasound Object in the Ultrasound Scene. |
| – UltrasoundSceneObjectQualifier | Qualifiers of the Ultrasound Object in the Ultrasound Scene. |
| SubUltrasoundSceneCount | Number of Sub-Ultrasound Scenes in the Ultrasound Scene. |
| SubUltrasoundScenes[] | Set of Data related to Ultrasound Objects in the Ultrasound Scene. |
| – SubOfflineMapSceneSpaceTime | Space and Time of Sub-Ultrasound Scene in the Ultrasound Scene. |
| DataXMData | Information on this Ultrasound Scene Geometry instance. |
| DescrMetadata | Descriptive Metadata |
5 Conformance Testing
A Data instance Conforms with Ultrasound Scene Geometry (OSD-USG) if:
- The Data validates against the Ultrasound Scene Geometry’s JSON Schema.
- All Data in the Ultrasound Scene Geometry’s JSON Schema
- Have the specified type
- Validate against their JSON Schemas
- Conform with their Data Qualifiers.